5.2025.405.1 - 21 King George Street VICTORIA PARK


The Town has received a development application for five double-storey dwellings at the above-mentioned property.

In accordance with Local Planning Policy 37 – Community Consultation on Planning Proposals, you are invited to comment on the following:

  • Street Setbacks –
    • Primary Street Setback – Clause 1 A1 (a) of the Local Planning Policy – Streetscape (LPP25) requires a minimum setback of 3.0 metres and an average setback of not less than 6.0 metres from the primary street boundary of King George Street. The application proposes a minimum setback of 2.1 metres to the dwelling wall and an average street setback of 3.75 metres.
    • Right-of-Way Setback – Clause 1 A3 (a) of the Town’s LPP25 requires Units 2 to 5 to be setback from the centreline of the right-of-way by
      • a minimum of 6.0 metres and a maximum of 7.0 metres to the ground floor walls of the dwelling; and
      • a minimum of 7.0 metres to the upper floor portion of a two-storey dwelling.

    The application proposes the following setbacks from the centreline of the right-of-way (ROW):

        • Units 2 and 3 – minimum of 4.8 metres to the ground floor wall of each dwelling and a minimum of 4.2 metres to the upper floor balconies.
        • Unit 4 –
            • south-western ROW boundary (ROW 51A) – a minimum of 4.21 metres to the ground floor wall and a minimum 4.21 metres to the upper floor wall.
            • north-western ROW boundary (ROW 51) – a minimum of 6.97 metres to the ground floor wall of the dwelling and a minimum 4.51 metres to the upper floor balcony. 
                • Unit 5 – a minimum 5.81 metres to the ground floor wall of the dwelling and a minimum 4.51 metres to the upper floor balcony.
            •  Lot Boundary Setbacks – Clause 3.4.1 and 3.4.2 of Part C of the Residential Design Codes Volume 1 (R-Codes) provides for a minimum lot boundary setback of 1.5 metres to the entire length of the upper floor. The application proposes a setback of 0.99 meters to a portion of the upper floor of Unit 5 to the north-eastern lot boundary (adjoining No. 17-19 King George Street). 
            • Site Works (Fill/Excavation and Retaining) within the Primary Street Setback Area – Clause 3.5 C3.5.1 of Part C of the R-Codes permits filling or excavation within 3 metres of the street alignment or between the street and a dwelling (whichever is the lesser) where it does not exceed 500mm from the natural ground level. The application proposes excavation between the King George Street front lot boundary and Unit 1 which ranges in depth from 0.647 metres to a maximum of 1.33 metres with associated stepped retaining ranging in height from 0.90 metres to a maximum of 1.387 metres.

            Please note that the abovementioned matters will be considered based on the merits of the case, and with regard to the relevant design principles and any comments received from nearby affected landowner(s) and occupier(s).

            The relevant design principles that the proposal will be assessed against are as listed below:

            Planning document 

            Council’s Local Planning Policy - Streetscape 

            Design element 

            Clause 1 – Setback of Buildings Generally 

            Relevant design principle(s) 

            P1. Buildings set back an appropriate distance to ensure they: 

            • contribute to the desired streetscape; 
            • provide adequate privacy for open space for dwellings; 
            • allow safety clearances for easements for essential service corridors; 
            • are consistent with the rhythm and scale of development in the street; 
            • promote the creation of new streetscape environments through the use of existing rights-of-ways; and  
            • protect residential amenity from disturbance from non-residential development abutting a right-of-way and provide safety of residential development add surveillance of the right-of-way. 

            Planning document 

            Residential Design Codes (R-Codes) Volume 1 

            Design element 

            3.4 Lot boundary setbacks 

            Relevant design principle(s) 

            P3.4.1 Lot boundary setbacks reinforce the location’s streetscape character and are consistent with the existing or desired built form local character.  

             

            P3.4.2 The setback of development from lot boundaries provides a transition between sites with different land uses or intensity of development.  

             

            P3.4.3 Buildings are set back from lot boundaries or adjacent buildings on the same lot to:  

            1. provide adequate solar access and natural ventilation to the building and open spaces on the site and adjoining properties; and  
            1. address the potential for overlooking and resultant loss of privacy on adjoining properties. 

            Planning document 

            Residential Design Codes (R-Codes) Volume 1 

            Design element 

            3.5 Site works and retaining walls 

            Relevant design principle(s) 

            P3.5.1 Development that considers and responds to the natural features of the site and requires minimal excavation/fill.  

             

            P3.5.2 Where excavation/fill is necessary, all finished levels respect the natural ground level at the lot boundary of the site and as viewed from the street. 

             

            P3.5.3 Retaining walls that result in land which can be effectively used for the benefit of residents, do not detrimentally affect the amenity of adjoining properties in the opinion of the decision-maker, and are designed, engineered and landscaped having due regard to the provisions of element 3.10 Visual privacy. 

            Survey

            I am the*This field is required.

            After considering the likely impact this proposal has on your property or suburb, do you*This field is required.


            Upload attachment

            Max File Size: 10.00 MB
            Allowed File Types: .avi, .doc, .docx, .gif, .jpeg, .jpg, .mov, .mp3, .mp4, .mpeg, .mpg, .pdf, .png, .ppt, .pptx, .xls, .xlsx
            Privacy and Personal Information

            Privacy and Personal Information

            In making a submission on a development application, you provide Council with personal information. This information will be held by Council to enable us to contact you in the course of consideration of the application and to ensure completeness of our records in relation to the application. Submissions are not confidential. They form part of the development application and may be included in reports to Council/ JDAP, and may be made available for public viewing.


            Get Audio Code

             
            Contact Details

            Name: Kelly Vilkson

            Job Title: Acting Coordinator Urban Planning

            Phone: 08 9311 8111

            Email: admin@vicpark.wa.gov.au

            FAQs

            Where can I view the application?

            How can I comment?

            How can I find out more information?

            Who will decide this application?

            If you've encountered a problem with the website or have any general feedback, please provide comment via this form.

            Was this page helpful?

            Get Audio Code